Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arq. bras. oftalmol ; 82(3): 195-199, May-June 2019. tab
Artigo em Inglês | LILACS | ID: biblio-1001305

RESUMO

ABSTRACT Purpose: To investigate changes in axial length after intravitreal dexamethasone implantation in patients with macular edema. Methods: We performed a prospective comparative study of 46 patients with unilateral macular edema, due to diabetic retinopathy, retinal vein occlusion, and non-infectious uveitis, who underwent dexamethasone implantation. The fellow eyes of the patients were considered the control group. The central macular thickness was measured by spectral-domain optical coherence tomography, and axial length was measured by IOLMaster 700 optical coherence biometry. We compared axial length and central macular thickness values within the groups. Results: In the study group, the baseline central macular thickness was 460.19 ± 128.64 mm, significantly decreasing to 324.00 ± 79.84 mm after dexamethasone implantation (p=0.000). No significant change in central macular thickness measurements was seen in the control group (p=0.244). In the study group, the baseline axial length was 23.16 ± 0.68 mm, significantly increasing to 23.22 ± 0.65 mm after dexamethasone implantation (p=0.039). However, the control group exhibited no significant change in axial length (p=0.123). Conclusions: In addition to significantly reducing central macular thickness measurements, intravitreal dexamethasone implantation also significantly changes optical biometry-based axial length measurements.


RESUMO Objetivo: Investigar alterações no comprimento axial após implante de dexametasona intravítrea em pacientes com edema macular. Métodos: Foi realizado um estudo prospectivo e comparativo de 46 pacientes com edema macular unilateral, devido à retinopatia diabética, oclusão da veia retiniana e uveíte não infecciosa, que foram submetidos ao implante de dexametasona. Os olhos contralateral de cada paciente foram considerados o grupo controle. A espessura macular central foi medida por tomografia de coerência óptica de domínio espectral, e o comprimento axial foi medido por meio de biometria de coerência óptica de domínio espectral e o comprimento axial foi medido pela biometria de coerência óptica com IOLMaster 700. Comparamos o comprimento axial e os valores da espessura macular central dentro dos grupos. Resultados: No grupo de estudo, a espessura macular basal foi de 460,19 ± 128,64 mm, diminuindo significativamente para 324,00 ± 79,84 mm após o implante de dexametasona (p=0,000). Nenhuma mudança significativa nas medidas da espessura macular central foi observada no grupo controle (p=0,244). No grupo de estudo, o comprimento axial basal foi de 23,16 ± 0,68 mm, aumentando significativamente para 23,22 ± 0,65 mm após o implante de dexametasona (p=0,039). No entanto, o grupo controle não apresentou alteração significativa no comprimento axial (p=0,123). Conclusões: Além de reduzir significativamente as medidas da espessura macular central, o implante de dexametasona intravítrea também altera significativamente as medidas de comprimento axial baseadas na biometria óptica.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Dexametasona/administração & dosagem , Edema Macular/tratamento farmacológico , Comprimento Axial do Olho/efeitos dos fármacos , Injeções Intravítreas/métodos , Glucocorticoides/administração & dosagem , Macula Lutea/efeitos dos fármacos , Acuidade Visual , Edema Macular/patologia , Estudos Prospectivos , Biometria/métodos , Resultado do Tratamento , Estatísticas não Paramétricas , Tomografia de Coerência Óptica/métodos , Retinopatia Diabética/tratamento farmacológico , Comprimento Axial do Olho/patologia , Macula Lutea/patologia
2.
Arq. bras. oftalmol ; 80(6): 382-385, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888168

RESUMO

ABSTRACT Purpose: To report follow-up data for patients who underwent XEN45 gel stent implantation, a new method of minimally invasive glaucoma surgery. Methods: Fifteen eyes in fifteen patients who underwent XEN45 gel stent implantation surgery were investigated in the study. All patients were examined preoperatively and at the following postoperative time points: 1 day; 1 and 2 weeks; and 1, 2, 3, 6, and 12 months. Intraocular pressure (IOP) was measured via Goldmann applanation tonometry. Combined surgical procedures (XEN45 + phacoemulsification + intraocular lens) were performed in patients who that had cataracts in addition to glaucoma. Results: The mean IOP values were significantly lower than the preoperative values at all postoperative visits (p<0.001). In two patients, the IOP exceeded 20 mmHg 12 months after surgery. These IOP increases were controlled by medical therapy, and none of the patients needed another surgical procedure. Conclusion: XEN45 gel stent implantation is a minimally invasive glaucoma surgery that ensures the effective reduction of IOP. This new treatment modality also avoids the destructive complications encountered in other invasive surgical procedures. However, further studies with greater numbers of patients and longer follow-up periods are needed to clarify certain points.


RESUMO Objetivo: Relatar os dados de acompanhamento dos pacientes que apresentaram implante de endoprótese de gel XEN45, um novo método de cirurgia de glaucoma minimamente invasiva. Métodos: Foram investigados quinze olhos de quinze pacientes que tiveram cirurgia de implante de endoprótese de gel XEN45 no estudo. Todos os pacientes foram examinados no pré-operatório e nos seguintes pontos de tempo pós-operatório: 1 dia; 1 e 2 semanas; E 1, 2, 3, 6 e 12 meses. A pressão intraocular foi medida pela tonometria de aplanamento de Goldmann. Procedimentos cirúrgicos combinados (XEN 45 + facoemulsificação + lente intraocular) foram realizados nos casos que apresentavam catarata além do glaucoma. Resultados: Os valores médios de PIO foram significativamente menores em todas as visitas pós-operatórias quando comparados aos valores pré-operatórios (p<0,001). Em 2 casos, os valores da pressão intraocular foram superiores a 20 mmHg aos 12 meses pós-operatório. Estes aumentos da pressão intraocular foram controlados por terapia médica, e nenhum dos pacientes necessitou de outro procedimento cirúrgico. Conclusão: Implantação de endoprótese de gel XEN45 é uma cirurgia de glaucoma minimamente invasiva que garante a redução efetiva da pressão intraocular. Esta nova modalidade de tratamento também evita as complicações destrutivas encontradas em outros procedimentos cirúrgicos invasivos. No entanto, estudos adicionais com um maior número de pacientes e períodos de acompanhamento mais longos são necessários para esclarecer certos pontos.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Stents , Glaucoma/cirurgia , Implantação de Prótese/métodos , Desenho de Prótese , Acuidade Visual , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA